2. Specifications
— 2-23 —
2.6.3. Cable Set
Caution : If you connect the cable to a moving part, be sure to use a flexible type
cable.
2.6.3.1. Stationary Cable
Caution : Bending radius of a Motor cable (ø 8) and resolver cable (ø 8) shall be
R43 mm or over.
Caution : Do not add the stress (tension, vibration, etc) to the cable and the
connector. It causes the disconnection and the loose connection.
Fig 2-30: Cable Set (Fixed type: M-C0×××SDP03)
2.6.3.2. Flexible Cable
Caution : Do not move the following parts.
A range of 200 [mm] from the end face of the Motor side receptacle housing
A range of 200 [mm] from the end face of the Driver Unit side plug assembly and
connector header
Caution : The bending radius of a Motor cable (ø 8) and resolver cable (ø 8) shall
be R80 mm or over. The radius of cables at the connecting position shall
be R40 mm or over.
Caution : Do not add the stress (tension, vibration, etc) to the cable and the
connector. It causes the disconnection and the loose connection.