9. Details of Command and Parameter
9-7
9.2.9. Adjusting
When setting the option code “/AR” to a parameter code, you may increase or decrease a value of
parameter by the keys + / -
The keys . and = change an increment or decrement of an input of the keys.
:VG/AJ
STEP 0.10
VG 6.00 _
Input of R key will reset to the shipping set.
Table 9-7: Keys to be used for adjustment
Key
Description
+
A press of the key increases a value as indicated.
-
A press of the key decreases a value as indicated.
.
A press of the key changes an increment or decrement the
step to 1/10 of current setting.
=
A press of the key changes an increment or decrement of the
step to 10 times of current setting.
R
A press of the key resets the value to the shipping set.
BS
A press of the key reset the value before adjustment and
terminates adjust mode.
ENT
A press of the key sets the value as adjusted and terminates
adjusting mode.
9.2.10. Output to Analog Monitor
The readout will be outputted to the primary analog monitor when the option code “/MN” is attached to
the parameter. In such a case, the default monitor offset or default range is specified.
Parameter MNY (Primary analog monitor offset) changes the offset.
Parameter MNR (Primary analog monitor range) changes the monitor range.
:LO/MN
MNR4000.000;_
The readout will be outputted to the secondary analog monitor when the option code “/MX” is attached to
the parameter. In such a case, the default monitor offset of default range is specified.
Parameter MXY (Secondary monitor offset) changes the offset.
Parameter MXR (Secondary analog monitor range) changes the monitor range.