8. More Advanced Function 
 
— 8-16 — 
8.3. Extended Control Output 
8.3.1.  In-zone Output: ZONEA, ZONEB, and ZONEC 
 The output reports that the Motor is in the predetermined zone.   
Table 8-14: Signal logic of outputs of ZONEA, ZONEB and ZONEC 
In the specified zone, or assuring the minimum output 
elapsing time.   
Table 8-15: Parameter related to the outputs ZONEA, ZONEB and ZONEC 
Start point of zone A 
Start point of zone B 
Start point of zone C 
End point of zone A   
End point of zone B 
End point of zone C 
Zone A stability timer 
Zone B stability timer 
Zone C stability timer 
 The parameters ZAS (Start point of zone A) and ZAE (End point of zone A) set the zone. The zone starts 
from the start point in the counting up direction of scale data and ends at the end point as shown in the 
figure below.   
  The zones B and C can be set by the parameters ZBS, ZBE, ZCS and ZCE respectively in the 
same way described above. . 
Fig 8-6: Setting of zone A 
 
In case of the paraemter DI0 
In case of the paraemter DI1 
 
ZAS: Start point of zone A   
 
ZAS:  Start  point  of  zone  A 
領域 A 開始点