7.  Operational  Function 
 
— 7-17 — 
7.2.6.2.  IPOS Mode (Parameter FW = 0) 
 This mode is to check if the current position defers from the target position of the positioning command.   
 Execution of positioning command, such as program operation, edits the target position. Thus, the output 
IPOS (In-position) will be forcibly opened. 
  The output opens at least for the time set in the parameter IS (In-position stability timer) to 
check stability of positioning, even no internal pulse is outputted.   
 Confirmation of settling stability starts when the Motor reaches to the target position. The IPOS output 
closes only when residual pulses in the error counter is less or equal to the setting of parameter IN; it 
opens in other states.   
Fig 7-14: Output IPOS in the operation caused by an internal command (IPOS mode) 
 
 In the pulse train command operation, the System always confirms completion of positioning every time 
inputting pulse pauses. If the intervals of inputting pulses are intermittent, set the parameter IS longer 
because the outputting IPOS signal will be unstable. 
Fig 7-15: Output IPOS in the pulse train command operation (IPOS mode)