9. Details of Command and Parameter
9-5
9.2.5. Wildcard Search
When a letter of alphabet is specified following the “?”, all corresponding commands and parameters will
be displayed.
When only the “?” is inputted, all commands and parameters will be displayed.
The prompt “;” is on the end of each line when reading out multiple commands or parameters.
In such a case, press the SP key to scroll to the next menu or terminate the readout by the BS
key
:?P
PG0.12;
PGL0.05;
PC0;
PS1;
PK0;
PWU0;
PWV0;
PWW0;
PF50.00
:
In the display in the terminal screen of EDD MegaTerm, all corresponding parameters and commands are
displayed in a screen.
9.2.6. Repeating Readout
When an option code “/RP” is added to a readout command such as the command TP, the System repeats
to display the readout.
A press of the BS key terminates repetitive readout.
:?SG/RP
SG 6 _
Adjust the parameter MR (Monitor refresh rate) when the settings of parameters are hard to read because
of their frequent changes. The readout stays on the display for a time set by the parameter MR for easy
confirmation of readout.