7. Operational Function
— 7-2 —
7.1.2. Alarm Clear: ACLR
This input clears a warning.
Table 7-3: Signal logic of the input ACLR
A rising signal of the input ACLR from OFF to ON clears a warning while the output WRN (Warning) is
closed.
The state of the Motor servo returns to the same condition before the warning is occurred. (Provided that
no input, such as the input SVON, is given to change the state of servo.
The table below lists the warning that is given by the output WRN.
Table 7-4: Warning to be reported by the output WRN
Command TA (Tell alarm status)
C0>Pulse Command/Feedback
Error
Error in the commanded position or
the feedback signal.
P5>Main AC Line Under Voltage
Low voltage of main power
Fig 7-2: Signal timing of the input ACLR
Output IPOS
(FW > 0: FIN)
Stops by the dynamic brake.
A warning occurs that makes the Motor servoe off.
Output IPOS
(FW < 0: CFIN)
(FW = 0: IPOS)
Max. 170 ms (Max. 3.2 s)
1
1) It takes 3.2 seconds to activate the
Motor servo for the first time after
turning on the main power.