8.  More  Advanced  Function 
 
— 8-13 — 
8.2.2.  Velocity Override: ORD 
 In the middle of positioning operation, the input ORD overrides the programmed velocity with the preset 
overriding rate. 
Table 8-8: Signal logic of the input ORD 
Override the programmed velocity.   
 When the input ORD is turned ON in the middle of positioning operation caused by an internal command, 
such as the command for positioning, jogging and Home Return, the Driver Unit overrides the 
programmed velocity and changes it according to the preset override change rate. 
Table 8-9: Parameter related to the input ORD   
 When the programmed velocity is overridden, the System changes the operating velocity with preset 
acceleration and deceleration.   
  The acceleration, deceleration and acceleration profiling for overriding velocity follow the 
programmed settings that has been dealt with. 
 When the ORD input activates during the operation of which programmed velocity is 
MV2.000 [s
-1
] and override ratio is OV150%, the target velocity is changed to 3 [s
-1
]. 
  The overridden velocity is limited to 10 [s
-1
]. When the override velocity exceeds the limit, it 
shall be limited to 10 [s
-1
]. 
Fig 8-3: Signal timing of the ORD input (In case of OV150) 
 
 
Fig 8-4: Signal timing of the ORD input: (In case of OV50)