2. Specifications
— 2-39 —
2.12. CN4: Motor Connector
Caution : Use the Cable Set provided with the Driver Unit. Please do not cut the
cable or hookup to other cable because the Cable Set is specially made
for the position sensor.
Table 2-28: Connector list
MSTBA2,5/8-G-5,08-LR or equivalent
FKC 2,5/8-ST-5,08-LR *or equivalent
* Provided with the Cable Set.
2.12.1. CN4 Pin-Out
Fig 2-44: Pin-out
External regeneration resistor terminal
External regeneration resistor terminal
External regeneration resistor thermal sensor input
External regeneration resistor thermal sensor input
2.12.2. CN4 Signal List
Table 2-29: Signal list
External regeneration resistor terminal
External regeneration resistor terminal
External regeneration resistor thermal sensor input*
External regeneration resistor thermal sensor input*
* Short these pins if external regeneration resistor is not in use. If they remain open,
the alarm of “over heat” occurs.)
Danger : Do not connect or disconnect the connector when the power of the Driver
Unit is on.
Danger : A high voltage is applied to the connector after the power is turned on.
Take extra care for short circuit.
Danger : Check the orientation of the connector when inserting it. Though the
connector is lock type, be sure to insert it to the bottom. Otherwise you
cannot secure the connector.
Danger : A high voltage remains between the pins R+ and R- even after the main
power is turned off. Be careful not to get an electric shock.
Danger : Operate the lever on both sides slowly when disconnecting the
connector.