8. More Advanced Function
8-42
Setting of control input and output
Let’s set signals for “Detection for error in the Motor System,” “Start operation• Hold operation” and
“Automatic servo on after the power on”.
Change the initial settings of the output NRM (Normal), the input HLD (Hold operation), and the input
SVON (Servo on).
The input SVON is not actually wired. However, its signal port has been set to the normally
closed polarity so that the Motor servo activates automatically when the power is on.
Fig 8-22: How to set the output NRM, input HLD and input SVON
:PO0
FNDRDY;
GC0;
ST0.0
?FNNRM
?
:PI6
FNSTP;
AB0;
NW0.2
?FNHLD
?AB1
?
:PI4
FNSVON;
AB0;
NW0.2
?AB1
?
:
Edit function of PO0 (CN2: Pin No. 3).
These are current settings. Input the SP key to scroll the
readout.
Input the SP key when the prompt ; is on the end of line.
ーを入力
Detection signal for error in the Motor System
Change the function of PO0 to NRM from DRDY.
Edit function of PI6 (CN2: Pin No. 9)
These are current settings. Input the SP key to
scroll the readout.
Input the SP key when the prompt ; is on the end of line.
Change the function of PI6 to HLD from STP.
Change contact polarity of the input HLD to normally closed.
Signal for Start operation Hold operation.
Preparation for
automatic Servo on
Change contact polarity of the SVON to normally closed.
Do not wire the signal so that the Motor servo activates
automatically when the power is turned on.
Edit the function of PI4 (CN2: Pin No. 7).