37
CJ2 CPU Unit Software User’s Manual
The following tables show the relationship between unit versions and CX-Programmer versions. Refer
to A-8 Functions Supported for Unit Versions for the functions supported by each unit version.
z Unit Versions and Programming Devices
*1 It is not necessary to upgrade the version of the CX-Programmer if functionality that was enhanced for the
upgrade of the CPU Unit will not be used.
*2 CX-Programmer version 8.2 or higher is required to use the functions added for unit version 1.1. The high-
speed interrupt function and changing the minimum cycle time setting in MONITOR mode, however, are also
supported by CX-Programmer version 8.02.
*3 A Programming Console cannot be used with a CJ2 CPU Unit.
z Pull-down List for PLC Models
Unit versions are not differentiated in the pull-down list for PLC models in the Change PLC Dialog
Box of the CX-Programmer. Select as shown in the following table regardless of the unit version.
Unit Versions and Programming Devices
CPU Unit Functions
Required Programming Device
CX-Programmer
Program-
ming
Console
Ver. 7.1
or lower
Ver. 8.0
Ver. 8.2
or higher
Ver.
9.0
Ver.
9.1
Ver. 9.12
or higher
CJ2H CJ2H-CPU6@-EIP
Unit version 1.0
Functions for unit version 1.0 --- OK OK OK OK OK
---
*3
CJ2H-CPU6@-EIP
Unit version 1.1
Functions
added for unit
version 1.1
Using new
functions
--- ---
OK
*2
OK OK OK
Not using
new functions
---
OK
*1
OK OK OK OK
CJ2H-CPU6@
Unit version 1.1
Functions
added for unit
version 1.1
Using new
functions
--- ---
OK
*2
OK OK OK
Not using
new functions
--- --- OK OK OK OK
CJ2H-CPU6@-EIP
Unit version 1.2
Functions
added for unit
version 1.2
Using new
functions
--- --- --- OK OK OK
Not using
new functions
---
OK
*1
OK
*1
OK OK OK
CJ2H-CPU6@
Unit version 1.2
Functions
added for unit
version 1.2
Using new
functions
--- --- --- OK OK OK
Not using
new functions
---
OK
*1
OK
*1
OK OK OK
CJ2H-CPU6@-EIP
Unit version 1.3
Functions
added for unit
version 1.3
Using new
functions
--- --- --- --- OK OK
Not using
new functions
---
OK
*1
OK
*1
OK OK OK
CJ2H-CPU6@
Unit version 1.3
Functions
added for unit
version 1.3
Using new
functions
--- --- --- --- OK OK
Not using
new functions
---
OK
*1
OK
*1
OK OK OK
CJ2M CJ2M-CPU@@ Unit
version 1.0
Functions for unit version 1.0 --- --- --- --- OK OK
CJ2M-CPU@@ Unit
version 2.0
Functions
added for unit
version 2.0
Using new
functions
--- --- --- --- --- OK
Not using
new functions
--- --- --- ---
OK
*1
OK
Series CPU Unit Model number
PLC model in Change PLC Dialog Box in CX-Programmer ver-
sion 9.0 or higher
CJ Series CJ2H CPU Unit CJ2H-CPU6@-EIP
CJ2H-CPU6@
CJ2H
CJ2M CPU Unit CJ2M-CPU3@
CJ2M-CPU1@
CJ2M