Section 10 Transferring Data 10-3 Data Transfer Using SPMA
NS-Designer Operation Manual
Make sure to select when transferring data through a PLC.
Select the communications method between
the computer and PLC, (Here, Serial
(Toolbus) is selected as an example.)
Select the communications method
between the PLC and PT. (Here, Ethernet
is selected as an example.)
6. Click the Set… Button on the right of the communications method setting. The following Serial
Setting Dialog Box will appear.
(1) Set the COM port to use to connect
the computer and PLC.
(2) Set the baud rate between the
computer and PLC.
(3) Set whether to detect the baud rate
between the computer and PLC.
(4) Input the response monitor time.
Increase the time only when there
are frequent communications error.
1 Port Set the COM port on the computer to use to connect the computer and
PLC.
2 Baud Rate Set the baud rate between the computer and PLC to 9600, 19200, 34700,
57600, or 115200.
3 Baud Rate Auto-Detect Set whether to detect the baud rate set for the peripheral port on the PLC.
The default is to detect the baud rate. If detection is disabled (pin 4 on the
PLC’s DIP switch is turned ON), set the baud rate in 2, above, to the same
speed as set for the peripheral port on the PLC.
4 Response Monitoring
Time
Input the response monitor time. Increase the time only when there are
frequent communications error.
7. Set the Port to the COM port to use to connect the computer to the PLC. Here COM1 is set as an
example.
8. Click the OK Button in the Serial Setting Dialog Box.
9. Click the Set… Button on the right of the NS and PLC Field. The Ethernet Setting Dialog Box
shown below will be displayed.