Message Countermeasure
No. of Address to find is out of range. Reset the address to search for within the allowable
range of addresses.
No. of functional objects inside a table ex-
ceeds the maximum limit (256).
Reduce the number of items horizontally or vertically in
the Table Setting Dialog Box so that the total number
of functional objects is 256 or less.
NS hardware error. Contact your OMRON service representative.
NS hardware is already connected. Restart
the NS hardware to change the communi-
cation method.
Restart the PT and make the new connection.
Operation failed. Check to see if the specified category or file has been
opened by another application and repeat the opera-
tion. It is also possible that data has been corrupted.
Other project exists in this directory. Can-
not create new one.
Specify another folder or create a new folder in which
to save the project file.
Please ensure that the maximum limit is not
smaller than minimum limit.
The lower limit is higher than the upper limit. Make the
correct limit settings.
Please enter an integer between oo and
oo.
Input an integer within the specified range.
Project cannot be specified as project
name because it is being edited with NS-
Designer, which has been started up al-
ready
Specify another project name, or stop editing the pro-
ject with NS-Designer and save the project.
Project file differs between transmission
source and destination. Select the whole
project and perform transmission again.
Individual screen data cannot be transferred for a dif-
ferent project when a project already exists in the PT
(or in the specified Memory Card bank). To transfer the
screen data, transfer the entire project.
Project file name contains invalid character.
Usable characters are alphanumeric (0-9,
A-Z, a-z), dollar mark ($), underscore (_)
and.
There are limits on transferable file names. Check the
error message and use NS-Designer to adjust the file
name accordingly. There are similar limits on notation
for text files indirectly accessed.
Project file name is too long. It should be
within 42 characters.
There are limits on transferable file names. Check the
error message and use NS-Designer to adjust the file
name accordingly. There are similar limits on notation
for text files indirectly accessed.
Specify the name of the project file to be processed. Project name is not set.
Correctly input an existing project name for project
maintenance.
Restore source data does not exist. Check
the data.
Check to see if the specification for the restore source
is correct.
Screen is not open. Either select the entire project for the Check When
setting on the Error Check Dialog Box or open the
screens to be checked and repeat the operation.
Screen page No. is out of range. Set a
number from 0 to 3999.
Set the screen number to a number between 0 and
3,999.
Screen size of download project is incor-
rect.
Mount Expansion Memory to the PT or take other
steps to increase the available memory in the PT.
Alternately, reduce the size of the screen data being
transferred.
The screen data size can be confirmed using Tools -
Resource Report.
Set PT Memory ($B/$W) both for $SB/$SW
Allocation Address or set host memory (DM
etc.) both for them.
Set the addresses for both $SB and $SW to PT mem-
ory addresses ($B and $W) or set them both to host
memory addresses for the same host.
Setting is not completed. Please be sure to
set this item.
Specify a data block.