142
Line Graphs Section 7-10
2. Double-click the line graph part and change the basic setup.
3. Make the display settings.
4. Click the Element Setup Tab and double-click row 0.
Double-click the parts num-
ber LG0 on the base screen,
and make the following set-
tings.
Function: Broken-
line Graph
Number of Lines: 1
Direction: Right
Update Device: W20
Display Point: 80
Reference
When the corresponding bit in the specified word for graph update turns ON,
the graph is updated. Graph 0 corresponds to bit 0, graph 1 to bit 1, and so on.
While the bit is OFF, the graph is not updated.
For a broken-line graph, sampling settings are not needed, so there is no need
to set the PT Configuration.
Set the basic setup.
Plot Interval (Dot): 1
Display Frame: Whole
Scale
Horizontal Line: On
Number of Divisions: 5
Vertical Line: On
Number of Divisions: 5