152
Alarm Lists (NV4W/NV3Q) Section 7-11
2. Double-click the alarm list part and select the basic setup.
3. Sets the color and form.
4. For Guidance, select Display Text and then make the necessary settings.
Operating Mode: Active List
Monitoring
Start Address: W30
Alarm Number
(i.e., number of
alarms): 32
Detection Type: Bit On
One bit is allocated to each
alarm. When 32 is set, 2
words can be monitored.
If an alarm status turns ON,
the alarm is displayed when
the bit turns ON.
The NV Configuration is not
necessary for an alarm list .
Set the basic setup.
Display Area
Number of Lines: 8
Display Frame: On
Type: Outside
Frame +
Inside
Frame
Color: Black
Color
String: Black
Background: White
Display Text: Yes
Display Area
Number of Lines: 5
Display Frame: On
Color: Black
Color
String: Black
Background: White
Guidance is used to display
a more detailed explanation
of a displayed alarm.
The Number of Lines in the
Guidance Area is given by
Number of Lines in the Dis-
play Area.