3-25
3-2 Servomotor Specifications
3
Specifications
*1. These are the values when the Servomotor is combined with a Servo Drive at room temperature (20C, 65%).
The maximum momentary torque indicates the standard value.
*2. Applicable Load Inertia
The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and
its rigidity. For a machine with high rigidity, operation is possible even with high load inertia. Select an
appropriate motor and confirm that operation is possible.
If the dynamic brake is activated frequently with high load inertia, the dynamic brake resistor may
burn. Do not repeatedly turn the Servomotor ON and OFF while the dynamic brake is enabled.
The dynamic brake is designed only for emergency stopping. Design the system to stop within about
three minutes after the dynamic brake operates.
*3. The allowable radial and thrust loads are the values determined for a service life of 20,000 hours at normal
operating temperatures.
The allowable radial loads are applied as shown in the following diagram.
*4. This is an OFF brake. (It is reset when excitation voltage is applied).
*5. The operation time is the value (reference value) measured with a surge suppressor (CR50500 manufac-
tured by Okaya Electric Industries Co., Ltd.).
Torque-Rotational Speed Characteristics for 3,000-r/min Flat Servomotors
3,000-r/min Flat Servomotors with 100-VAC Power Input
The following graphs show the characteristics with a 3-m standard cable and a 100-VAC input.
R88M-GP10030L/S (100 W) R88M-GP20030L/S (200 W) R88M-GP40030L/S (400 W)
3,000-r/min Flat Servomotors with 200-VAC Power Input
The following graphs show the characteristics with a 3-m standard cable and a 200-VAC input.
R88M-GP10030H/T (100 W) R88M-GP20030H/T (200 W) R88M-GP40030H/T (400 W)
Radial load
Thrust load
Center of shaft
(
LR/2
)
0.5
0 1000 2000 3000 4000
5000
1.0
0.84
0.32 0.32
0.32
0.19
0.84 (3500)
Repetitive usage
Continuous usage
(N·m)
(r/min)
1.0
0 1000 2000 3000 4000
5000
2.0
1.8
0.64 0.64
0.38
1.8 (3400)
Repetitive usage
Continuous usage
(N·m)
(r/min)
2.0
0 1000 2000 3000 4000
4500
4.0
3.6
1.3 1.3
1.5
0.78
3.6 (3300)
Repetitive usage
Continuous usage
(N·m)
(r/min)
0.5
0 1000 2000 3000 4000
5000
1.0
0.86
0.32 0.32
0.19
0.86
Repetitive usage
Continuous usage
(N·m)
(r/min)
1.0
0 1000 2000 3000 4000
5000
2.0
1.8
0.64
0.38
0.64
1.8 (4500)
Repetitive usage
Continuous usage
(N·m)
(r/min)
2.0
0 1000 2000 3000 4000
5000
4.0
3.65
1.3 1.3
2.0
0.78
3.65 (
3600)
Repetitive usage
Continuous usage
(N·m)
(r/min)