4-10
4-1 Installation Conditions
System Design
4
Installing Decelerator into the Machine
When you install the R88G-VRXF into the machine, confirm that the mounting surface is flat
and there are no burrs on the tap sections, and fix the mounting flange with bolts.
Bolt tightening torque on the mounting flange (for aluminum)
Note If the key on a Servomotor with key is uninstalled, it is possible to use the Decelerator by
installing the Servomotor without above mentioned key.
Slipping does not occur.
R88G-VRXF B C D
Number of bolts 4 4 4
Size of bolts M5 M6 M8
Mounting PCD (mm) 60 90 115
Tightening torque (N·m) 5.8 9.8 19.6