6-16
6-4 Setting the Mode
Operation
6
Warning Display
Regeneration Load Ratio
Displays the regeneration resistance load ratio as a percentage of the detection level for the
regeneration load.
Overload Load Ratio
Displays the load ratio as a percentage of the rated load.
Inertia Ratio
Total Feedback Pulses and Total Command Pulses
Displays the total number of pulses after the power supply is turned ON.
The display will overflow as shown in the following figure.
Use the key to switch the display between the upper and lower digits of the total number of
pulses.
Hold down the key for 5 s or longer to reset the total pulses to 0.
Automatic Servomotor Recognition
: No warning,
: Warning
Overload: 85% or more of the alarm level for
overload.
Battery warning: Absolute encoder battery voltage dropped to 3.2 V or less
Fan lock: Abnormal cooling fan speed.
Over-regeneration: 85% or more of the alarm level for regeneration
overload.
The alarm level will be 10% of the operating ratio of the regeneration
resistance if the Regeneration Resistor Selection (Pn06C) is set to 1.
Displays the inertia ratio as a percentage.
2,147,483,647 pulses
−
2,147,483,647 pulses
−
2,147,483,647 pulses
Power ON
0
ForwardReverse
Upper digits
Lower digits
Hk-k2k1kk4k7
4k8k3k6k4k7
Automatic recognition enabled (Always this indication is displayed.)