GUI reference
R&S
®
ZNA
743User Manual 1178.6462.02 ─ 20
"Trace Cumulative Low Color" is the color that is used for the occurrence value 1,
"Trace Cumulative High Color" is the color that is used for the most frequent occurren-
ces. No occurrence (value 0) is always displayed fully transparent with the background
being visible.
OK / Cancel
"OK" enables/modifies the eye diagram, "Cancel" leaves the Eye Diagram dialog with-
out applying possible changes.
Remote command:
CALCulate<Chn>:EYE:STATe
5.17.2.6 Advanced Settings dialog
The "Advanced Settings" dialog gives full access to the calculation chain of the eye
diagram simulation.
Access: System – [Applic] > "TDR" > "Eye Diag" > "Advanced Settings..."
This dialog is available with Extended time domain analysis option R&S ZNA-K20 only.
Controls in the dialog
Generator, Emphasis, Jitter and Noise allow you to specify the simulated input sig-
nal of the DUT
DUT allows you to switch between different transmission (and reflection) paths of
the DUT and to configure its DC properties.
Equalization allows you to perform signal equalization at the "virtual receiver".
A green LED indicates that the respective building block is active. However the calcula-
tion chain can also be shortened using the [Slider] control below the building blocks.
[Slider]
Allows you to shorten the simulation/calculation chain without deactivating the building
blocks at the tail end.
Remote command:
CALCulate<Chn>:EYE:VIEW
Define Colors...
See "Define Colors" on page 742
Applic softtool

Table of Contents