Model 8210/8250 Maintenance Manual Section 3. Systems Overview
Operator Display and Programming
Publication:1146945/001, Revised: 25 Sep 2018 3-11
16 Travel Alarm
Type
0 to 7 1 0 0 = No Alarm
1 = Tractor-First Alarm
2 = Forks-First Alarm
3 = All Travel Alarm
4 = Low Battery Alarm
5 = Low Battery and Forks-First Travel
Alarm
6 = Low Battery and Tractor-First Travel
Alarm
7 = Low Battery and All Travel Alarm
17 Not used
18 iPORT Init
Speed
(only with
iWAREHOUSE
option)
0.1 to 3.9
repre-
senting 0
MPH to
FULL
SPEED
0.1 3.8 Prior to communication with the SWM,
iPORT Initial Speed sets the maximum
allowable truck speed.
NOTE: A 0 MPH setting disables truck
functions.
NOTE: Raymond recommends that Init
Speed be set to 0.5 (0.8 km/h) to
prevent operation without being
logged in.
19 iPORT Error
Speed
(only with
iWAREHOUSE
option)
0.1 to 3.9
repre-
senting 0
MPH to
FULL
SPEED
0.1 3.8 The Error Speed limit is activated when
communication is interrupted and the
truck comes to a stop. The truck is
limited to Error speed while traveling
down to 1.0 MPH (1.6 km/h). Once
stopped, the lower speed is activated if
Error Speed is set to less than 1.0 MPH
(1.6 km/h). When communication is
re-established, and throttle is brought
back to neutral, normal operation is
restored.
NOTE: Raymond recommends that
Error Speed be set to 1.0 MPH
(1.6 km/h).
20 Hour Meter
Selection
1 to 3 1 2 1 (A) = key time
2 (b) = activity time (drive, lift, or lower)
3 (c) = travel time
21 Battery Type 1 to 4 1 2 Defines battery type for correct BSOC
(battery state-of-charge) configuration.
1 = Industrial battery (8.5 inch)
2 = AGM battery
3 = Wet Cell battery and 7.5 inch
NEXSYS battery pack
4 = 5 inch NEXSYS battery Slim Pack
Model 8250: This setting has no effect
with the CAN based lithium-ion battery.
22 Not used
23 Not used
Parameter Name Unit Range Step Default Description