Section 3. Systems Overview Model 8210/8250 Maintenance Manual
Operator Display and Programming
3-12 Publication: 1146945/001, Revised: 25 Sep 2018
24 Battery Reset
Level
50 to
100%
1 75% Reset value for BSOC function. The
displayed BSOC value must be below the
selected level at key OFF before a fully
charged battery will reset BSOC to 100%
at key ON or reset to 100% when the
voltage at key OFF is above the reset
level. When battery BSOC level drops
below this level, the truck will allow the
BSOC to reset once Reset Voltage
(Parameter 44) is reached.
Model 8250: This setting has no effect
with the CAN based lithium-ion battery.
25 Not used
26 Sequencing
Delay
100 to
500 ms
20 200 ms Creates a sequencing delay to allow for
throttle engagement just before the brake
is released. The Sequencing Delay timer
is enabled when the throttle is engaged
while the brake is applied. If the timer
expires before the brake is released, error
code ‘Hpd’ is generated by the VM.
27 Not used
28 Not used
29 Fork Height /
Travel Speed
Configuration
(Lift and Go)
0 to 15 1 0
Monitors lift/lower requests. The travel
speed is ‘X’ until the ‘Y’ condition is met.
0: No restrictions
1: X = 1 MPH, Y = Lift for 0.25 seconds
2: X = 1 MPH, Y = Lift for 0.50 seconds
3: X = 1 MPH, Y = Lift for 1.0 seconds
4: X = 1 MPH, Y = Lift for 1.5 seconds
5: X = 1 MPH, Y = Lift timeout not
activated
6: X = 2 MPH, Y = Lift for 0.25 seconds
7: X = 2 MPH, Y = Lift for 0.50 seconds
8: X = 2 MPH, Y = Lift for 1.0 seconds
9: X = 2 MPH, Y = Lift for 1.5 seconds
10: X = 2 MPH, Y = Lift timeout not
activated
11: X = 3 MPH, Y = Lift for 0.25 seconds
12: X = 3 MPH, Y = Lift for 0.50 seconds
13: X = 3 MPH, Y = Lift for 1.0 seconds
14: X = 3 MPH, Y = Lift for 1.5 seconds
15: X = 3 MPH, Y = Lift timeout not
activated
30 iPORT Basic
(only with
iWAREHOUSE
option)
0 or 1 1 0 Requires the operator to login before
truck operation is allowed.
0 = OFF
1 = ON
NOTE: This parameter is Read Only
except when using FlashWare.
Parameter Name Unit Range Step Default Description
Property of American Airlines