Model 8210/8250 Maintenance Manual Section 3. Systems Overview
Operator Display and Programming
Publication:1146945/001, Revised: 25 Sep 2018 3-13
31 iALERT
(only with
iWAREHOUSE
option)
0 or 1 1 0 Requires the operator to login before
truck operation is allowed. Enables
caution and error codes to be sent to the
iWAREHOUSE system.
0 = OFF
1 = ON
NOTE: This parameter is Read Only
except when using FlashWare.
32 iCONTROL
(only with
iWAREHOUSE
option)
0 or 1 1 0 Requires the operator to login before
truck operation is allowed. Enables
remote setting of operator parameters.
0 = OFF
1 = ON
NOTE: This parameter is Read Only
except when using FlashWare.
33 Not used
34 iBATTERY
(only with
iWAREHOUSE
option)
0 to 2 1 0 Identifies the source of BSOC display
information.
0 = OFF
1 = ON and displayed BSOC is from the
TA
2 = ON and displayed BSOC is from the
BSM
NOTE: This parameter is Read Only
except when using FlashWare.
35 Not used
36 Not used
37 Not used
38 Not used
39 Access Code 1 to 4 1 1 Defines whether truck has a Main
ON/OFF switch or a keypad and what
access level service personnel have to
parameters.
1 = ON/OFF switch (no key pad) and
driver parameters are open,
2 = ON/OFF switch (no key pad) and
driver parameters are closed,
3 = keypad and driver parameters are
open,
4 = keypad and driver parameters are
closed.
NOTE: When driver parameters are
closed, a Service Key or
FlashWare is required to access
driver parameters.
40 Not used
Parameter Name Unit Range Step Default Description
Property of American Airlines