Section 25 Electrical Characteristics
Rev. 4.00 Sep. 14, 2005 Page 956 of 982
REJ09B0023-0400
25.3.9 Multi Function Timer Pulse Unit Timing
Table 25.10 lists the multi function timer pulse unit timing.
Table 25.10 Multi Function Timer Pulse Unit Timing
Conditions: V
CC
= 1.8 V ± 5%, V
CC
Q = AV
CC
= 3.0 V to 3.6 V, V
SS
= V
SS
Q = AV
SS
= 0 V,
Ta = 40°C to +85°C
Item Symbol Min. Max. Unit Figure(s)
Output compare output delay time t
TOCD
B
cyc
/2 + 20 ns 25.47
Input capture input setup time t
TICS
B
cyc
/2 + 20 ns
Timer input setup time t
TCKS
B
cyc
/2 + 20 ns 25.48
Timer clock pulse width (single edge) t
TCKWH/L
1.5 t
pcyc
Timer clock pulse width (both edges) t
TCKWH/L
2.5 t
pcyc
Timer clock pulse width
(phase counting mode)
t
TCKWH/L
2.5 t
pcyc
CKIO
Output compare
output
Input capture
input
t
TOCD
t
TICS
Figure 25.47 MTU Input/Output Timing
CKIO
TCLKA to
TCLKD
t
TCKS
t
TCKS
t
TCKWH
t
TCKWL
Figure 25.48 MTU Clock Input Timing