EasyManua.ls Logo

Renesas HD6417641 - Table 18.20 TIOR_1 (Channel 1)

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 542 of 982
REJ09B0023-0400
Table 18.20 TIOR_1 (Channel 1)
Description
Bit 3
IOA3
Bit 2
IOA2
Bit 1
IOA1
Bit 0
IOA0
TGRA_1
Function
TIOC1A Pin Function
0 0 0 0 Output hold*
1
Output
compare
register
Initial output is 0
0 output at compare match
1 0 Initial output is 0
1 output at compare match
1 Initial output is 0
Toggle output at compare match
1 0 0 Output hold*
1 Initial output is 1
0 output at compare match
1 0 Initial output is 1
1 output at compare match
1 Initial output is 1
Toggle output at compare match
1 0 0 0 Input capture at rising edge
1 Input capture at falling edge
1 X Input capture at both edges
1 X X
Input
capture
register
Input capture at generation of channel
0/TGRA_0 compare match/input capture
[Legend]
X: Don't care
Note: * The low level output is retained until TIOR contents is specified after a power-on reset
and entering standby mode.