EasyManua.ls Logo

Renesas HD6417641 - AC Bus Timing; Table 25.8 Bus Timing

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 25 Electrical Characteristics
Rev. 4.00 Sep. 14, 2005 Page 923 of 982
REJ09B0023-0400
25.3.3 AC Bus Timing
Table 25.8 Bus Timing
Conditions: Clock mode 2/6/7, V
CC
Q = 3.0 V to 3.6 V, V
SS
Q = 0 V, Ta = 40°C to +85°C
Bφ = 50 MHz*
Item Symbol Min. Max. Unit Figure(s)
Address delay time 1 t
AD1
1 12 ns 25.13 to 25.39
Address delay time 2 t
AD2
1/2t
cyc
1/2t
cyc
+ 12 ns 25.22
Address delay time 3 t
AD3
1/2t
cyc
1/2t
cyc
+ 12 ns 25.40, 25.41
Address setup time t
AS
0 ns 25.13 to 25.18
Address hold time t
AH
0 ns 25.13 to 25.17
BS delay time t
BSD
12 ns 25.13 to 25.36
CS delay time 1 t
CSD1
1 12 ns 25.13 to 25.39
CS delay time 2 t
CSD2
1/2t
cyc
1/2t
cyc
+ 12 ns 25.40, 25.41
Read write delay time 1 t
RWD1
1 12 ns 25.13 to 25.39
Read write delay time 2 t
RWD2
1/2t
cyc
1/2t
cyc
+ 12 ns 25.40, 25.41
Read strobe delay time t
RSD
1/2t
cyc
1/2t
cyc
+ 12 ns 25.13 to 25.18,
25.20 to 25.22
Read data setup time 1 t
RDS1
1/2t
cyc
+ 8 ns 25.13 to 25.18,
25.20, 25.21
Read data setup time 2 t
RDS2
8 ns 25.23 to 25.26,
25.31 to 25.33
Read data setup time 3 t
RDS3
1/2t
cyc
+ 8 ns 25.22
Read data setup time 4 t
RDS4
1/2t
cyc
+ 8 ns 25.40
Read data hold time 1 t
RDH1
0 ns 25.13 to 25.18,
25.20
Read data hold time 2 t
RDH2
2 ns 25.23 to 25.26,
25.31 to 25.33
Read data hold time 3 t
RDH3
0 ns 25.22
Read data hold time 4 t
RDH4
1/2t
cyc
+ 5 ns 25.40
Write enable delay time 1 t
WED1
1/2t
cyc
1/2t
cyc
+ 12 ns 25.13 to 25.18,
25.20
Write enable delay time 2 t
WED2
12 ns 25.21

Table of Contents