EasyManua.ls Logo

Renesas HD6417641 - Figure 18.109 Error Occurrence in Complementary PWM Mode, Recovery in Reset-Synchronous PWM Mode

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 668 of 982
REJ09B0023-0400
(25) Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Reset-Synchronous PWM Mode
Figure 18.109 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in reset-synchronous PWM mode.
1
RESET
2
TOCR
3
TMDR
(CPWM)
5
PFC
(MTU)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(normal)
12
TOER
(0)
13
TOCR
14
TMDR
(RPWM)
15
TOER
(1)
16
PFC
(MTU)
17
TSTR
(1)
High-Z
High-Z
High-Z
MTU module
output
TIOC3A
TIOC3B
TIOC3D
Port output
TIOC3B/PTE[6]
TIOC3A/PTE[7]
TIOC3D/PTE[4]
Figure 18.109 Error Occurrence in Complementary PWM Mode,
Recovery in Reset-Synchronous PWM Mode
1 to 10 are the same as in figure 18.105.
11. Set normal mode. (MTU output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the reset-synchronous PWM mode output level and cyclic output enabling/disabling
with TOCR.
14. Set reset-synchronous PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU output with the PFC.
17. Operation is restarted by TSTR.

Table of Contents