EasyManua.ls Logo

Renesas HD6417641 - Figure 18.94 Error Occurrence in PWM Mode 1, Recovery in Phase Counting Mode

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 653 of 982
REJ09B0023-0400
(10) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Phase Counting Mode
Figure 18.94 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in phase counting mode after re-setting.
1
RESET
2
TMDR
(PWM1)
3
TOER
(1)
5
PFC
(MTU)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PCM)
12
TIOR
(1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
• Not initialized (TIOC*B)
High-Z
High-Z
MTU module
output
TIOC*A
TIOC*B
Port output
TIOC*A/PTE[n]
TIOC*B/PTE[n]
n = 0 to 15
Figure 18.94 Error Occurrence in PWM Mode 1, Recovery in Phase Counting Mode
1 to 10 are the same as in figure 18.91.
11. Set phase counting mode.
12. Initialize the pins with TIOR.
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is
not necessary.

Table of Contents

Related product manuals