EasyManua.ls Logo

Renesas HD6417641 - Figure 25.1 Power-On Sequence; Power-On Sequence

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 25 Electrical Characteristics
Rev. 4.00 Sep. 14, 2005 Page 908 of 982
REJ09B0023-0400
25.1.1 Power-On Sequence
Supply the power so that VccQ (3.3-V system) and Vcc (1.8-V system) are supplied
simultaneously or Vcc is supplied after VccQ is supplied.
Recommended values for the power-on procedure are shown below.
V
CC
Q (min.) voltage
V
CC
Q: 3.3 V-system power supply
V
CC
: 1.8 V-system power supply
V
CC
(min.) voltage
t
pwu
t
unc
GND
V
CC
/2 level voltage
The time at which VccQ
reaches V
CC
Q (min.)
The time at which Vcc
reaches V
CC
(min.)
Unsettling opration Normal operation Operation stopped
Clock starts oscillation
Oscillation settling time (10 ms)
Power-on reset released and then
normal operation started
t
pwd
Figure 25.1 Power-On Sequence

Table of Contents