Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 568 of 982
REJ09B0023-0400
TCNT value
H'0180
H'0000
TIOCA
TGRA
H'0010
H'0005
Counter cleared by TIOCB
input (falling edge)
H'0160
H'0005 H'0160 H'0010
TGRB
H'0180
TIOCB
Time
Figure 18.10 Example of Input Capture Operation
18.4.2 Synchronous Operation
In synchronous operation, the values in a number of TCNT counters can be rewritten
simultaneously (synchronous presetting). Also, a number of TCNT counters can be cleared
simultaneously by making the appropriate setting in TCR (synchronous clearing).
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 4 can all be designated for synchronous operation.

Table of Contents

Related product manuals