EasyManua.ls Logo

Renesas HD6417641 - Figure 20.11 EP2 Bulk-IN Transfer Operation

Renesas HD6417641
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 20 USB Function Module
Rev. 4.00 Sep. 14, 2005 Page 777 of 982
REJ09B0023-0400
USB function
Application
IN token reception
Data transmission to host
Clear EP2 transfer
request flag
(USBIFR0/EP2 TR = 0)
Enable EP2 FIFO
empty interrupt
(USBIER0/EP2 EMPTY = 1)
USBIER0/EP2 EMPTY
interrupt
Write one packet of data
to USBEP2 data register
(USBEPDR2)
Write 1 to EP2 packet
enable bit
(USBTRG/EP2 PKTE = 1)
Set EP2
empty status
(USBIFR0/EP2
EMPTY = 1)
Valid data
in EP2 FIFO?
NACK
ACK
Interrupt request
Yes
No
Clear EP2 empty status
(USBIFR0/EP2 EMPTY = 0)
Space
in EP2 FIFO?
No
Yes
Interrupt
request
Figure 20.11 EP2 Bulk-IN Transfer Operation