Table 18.14 TIORH_3 (Channel 3)
Description
Bit 7
IOB3
Bit 6
IOB2
Bit 5
IOB1
Bit 4
IOB0
TGRB_3
Function
TIOC3B Pin Function
0 0 0 0 Output hold*
1
Output
compare
register
Initial output is 0
0 output at compare match
1 0 Initial output is 0
1 output at compare match
1 Initial output is 0
Toggle output at compare match
1 0 0 Output hold*
1 Initial output is 1
0 output at compare match
1 0 Initial output is 1
1 output at compare match
1 Initial output is 1
Toggle output at compare match
1 X 0 0 Input capture at rising edge
1 Input capture at falling edge
1 X
Input capture
register
Input capture at both edges
[Legend]
X: Don't care
Note: * The low level output is retained until TIOR contents is specified after a power-on reset
and entering standby mode.