Display Count: Uncapped Time Length
7-006-001 ENV:ACL DECAPTIM
Use this SP to display the total time length when the maintenance unit's cap is
released from the print head.
Display Count: Need for Ink Circulation Sequence
7-007-001 JDG:LIQUID MNT
Use this SP to display if it is necessary to perform ink circulation sequence.
0bit for Print Head 1
1bit for Print Head 2
1: Ink circulation sequence needed
0: Ink circulation sequence not needed
Display: Print Head Temperature during the Last Air-Purge/Ink Re-filling
7-008-001 TEMP:DIFF POS:H1 Print Head 1 (C / K)
7-008-002 TEMP:DIFF POS:H2 Print Head 2 (Y / M)
Use this SP to display the print head temperature during the last time air-purge/ink
tank re-filling was performed.
Display: Print Head Humidity during the Last Air-Purge/Ink Re-filling
7-009-001 HUMI:DIFF POS:H1 Print Head 1 (C / K)
7-009-002 HUMI:DIFF POS:H2 Print Head 2 (Y / M)
Use this SP to display the print head humidity during the last time air-purge/ink tank
re-filling was performed.
Display: Temperature during the Last Maintenance
7-010-001 HTEMP:FIN MNT:H1 Print Head 1 (C / K)
2. Appendix: SP Mode Tables
72