EasyManua.ls Logo

Rohde & Schwarz ESW Series - Trace Configuration; Trace Export

Rohde & Schwarz ESW Series
759 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Common Analysis and Display Functions
R&S
®
ESW
211User Manual 1177.6298.02 ─ 08
11.3.2 Trace Configuration
A trace is a collection of measured data points. The trace settings determine how the
measured data is analyzed and displayed on the screen.
Trace configuration for the scan diagram
The contents of the "Traces" tab of the "Trace Configuration" are the same as the
Traces / Final Meas tab of the "Test Automation" dialog box.
Trace configuration for IF analysis
IF analysis supports a maximum of three traces. The "Traces" dialog box available for
IF analysis supports the following functions:
"Trace Mode" on page 132
"Predefined Trace Settings - Quick Config" on page 211
Additional trace configuration features
In addition, the "Trace Configuration" for scans provides the following functionality.
Predefined Trace Settings - Quick Config................................................................... 211
Predefined Trace Settings - Quick Config
Commonly required trace settings have been predefined and can be applied very
quickly by selecting the appropriate button.
Function Trace Settings
Preset All Traces Trace 1: Clear Write
Blank
Set Trace Mode
Max | Avg | Min
Trace 1: Max Hold
Trace 2: Average
Trace 3: Min Hold
Blank
Set Trace Mode
Max | ClrWrite | Min
Trace 1: Max Hold
Trace 2: Clear Write
Trace 3: Min Hold
Blank
11.3.3 Trace Export
Access: "Overview" > "Analysis" > "Traces" > "Trace Export"
The R&S ESW provides various evaluation methods for the results of the performed
measurements. If you want to evaluate the data with other, external applications, you
can export the measurement data to a standard ASCII format file (DAT or CSV).
Trace Configuration

Table of Contents