Remote Commands in the Receiver Application
R&S
®
ESW
475User Manual 1177.6298.02 ─ 08
WRITe
Overwrites the trace when a new measurement begins.
*RST: Depends on the trace number.
Example: //Select trace mode and display the highest value obtained over
5 measurements
DISP:TRAC2:MODE MAXH
SENS:SWE:COUN 5
Manual operation: See "Trace Mode" on page 132
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>[:STATe] <State>
This command turns a trace on and off.
The measurement continues in the background.
Suffix:
<n>
.
Window
Irrelevant in the Receiver application.
<w> subwindow
<t> Trace
Example:
DISP:TRAC3 ON
15.5.10 Final Results
CALCulate<n>:FMEasurement:PLISt<pi>:ALL?................................................................ 475
CALCulate<n>:FMEasurement:PLISt<pi>:COMMent......................................................... 476
CALCulate<n>:FMEasurement:PLISt<pi>:DELTa?.............................................................476
CALCulate<n>:FMEasurement:PLISt<pi>:DETector...........................................................477
CALCulate<n>:FMEasurement:PLISt<pi>:FREQuency?.................................................... 477
CALCulate<n>:FMEasurement:PLISt<pi>:LEVel............................................................... 477
CALCulate<n>:FMEasurement:PLISt<pi>:SIZE?...............................................................478
CALCulate<n>:FMEasurement:PLISt<pi>:TRACe?............................................................478
CALCulate<n>:FMEasurement:PLISt<pi>[:DATA]?............................................................ 478
CALCulate<n>:FMEasurement:PLISt<pi>:ALL?
This command queries the information for all peaks measured in the final measure-
ment.
Suffix:
<n>
.
irrelevant
<pi> irrelevant
Return values:
<FinalResults> List of values representing all measured peaks. The size of the
list depends on the number of peaks measured in the final mea-
surement.
For each peak, the command returns the following information.
Measurements and Result Displays