EasyManua.ls Logo

Rohde & Schwarz ESW Series - Measurement Channel Synchronization

Rohde & Schwarz ESW Series
759 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands in the Receiver Application
R&S
®
ESW
648User Manual 1177.6298.02 ─ 08
Suffix Description
CMAP39 *) Table Value – Background
CMAP40 Trace 5
CMAP41 Trace 6
*) these settings can only be defined via the theme (DISPlay:THEMe:SELect on page 646) and are thus
ignored in the SCPI command
15.9.6 Measurement Channel Synchronization
General Coupling Manager...................................................................................648
Custom Coupling Manager................................................................................... 653
15.9.6.1 General Coupling Manager
Commands to configure parameter coupling described elsewhere.
OUTPut<ou>:LINK on page 499
INSTrument:COUPle:ACDC............................................................................................ 648
INSTrument:COUPle:ATTen............................................................................................ 649
INSTrument:COUPle:BWIDth.......................................................................................... 649
INSTrument:COUPle:BANDwidth.....................................................................................649
INSTrument:COUPle:CENTer..........................................................................................649
INSTrument:COUPle:DEMod.......................................................................................... 650
INSTrument:COUPle:GAIN............................................................................................. 650
INSTrument:COUPle:LLINes...........................................................................................650
INSTrument:COUPle:LIMit.............................................................................................. 650
INSTrument:COUPle:MARKer.........................................................................................651
INSTrument:COUPle:PRESel..........................................................................................651
INSTrument:COUPle:PROT............................................................................................ 651
INSTrument:COUPle:SPAN.............................................................................................652
INSTrument:COUPle:VBW..............................................................................................652
INSTrument:COUPle:ACDC <State>
This command turns synchronization of the AC / DC Coupling state between measure-
ment channels on and off.
Parameters:
<State> ALL | 1
Turns on synchronization.
NONE | 0
Turns off synchronization.
*RST: ALL
Example:
INST:COUP:ACDC ALL
Synchronizes the "AC/DC Coupling" parameter.