EasyManua.ls Logo

Rohde & Schwarz ESW Series - Page 438

Rohde & Schwarz ESW Series
759 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands in the Receiver Application
R&S
®
ESW
438User Manual 1177.6298.02 ─ 08
Table 15-2: Available channel types and default channel names
Application <ChannelType> Parameter Default Channel Name*)
Receiver RECeiver Receiver
CISPR APD n/a
Use CALCulate:
STATistics:CAPD[:STATe]
Use
CALCulate:STATistics:
CAPD[:STATe]
CISPR APD
Spectrum SANalyzer Spectrum
I/Q Analyzer IQ IQ Analyzer
Real-Time Spectrum RTIM Real-Time Spectrum
Analog Demodulation ADEMod Analog Demod
Note: the default channel name is also listed in the table. If the specified name for a new channel already
exists, the default name, extended by a sequential number, is used for the new channel.
INSTrument:REName <ChannelName1>, <ChannelName2>
This command renames a channel.
Setting parameters:
<ChannelName1> String containing the name of the channel you want to rename.
<ChannelName2> String containing the new channel name.
Note that you cannot assign an existing channel name to a new
channel; this will cause an error.
Channel names can have a maximum of 31 characters, and
must be compatible with the Windows conventions for file
names. In particular, they must not contain special characters
such as ":", "*", "?".
Example:
INST:REN 'Receiver','REC'
Renames the channel with the name 'Receiver' to 'REC'.
Usage: Setting only
INSTrument[:SELect] <ChannelType> | <ChannelName>
This command activates a new channel with the defined channel type, or selects an
existing channel with the specified name.
Also see
INSTrument:CREate[:NEW] on page 436
Parameters:
<ChannelType> Channel type of the new channel.
For a list of available channel types see INSTrument:LIST?
on page 437.
Application Selection

Table of Contents