SAM4s ER-900 Series Operator's & Programming Manual v.1.28 P-Mode Programming • 167
#/NS - Function Key Options
Options - Program 70 (P-Mode)
Address OPTION VALUE = SUM
N1
No Sale is inactive? Yes = 1
No = 0
No Sale active in X control lock position
only?
Yes = 2
No = 0
No Sale inactive after non-add # entry? Yes = 4
No = 0
N2
Enforce non-add # entry at start of sale? Yes = 1
No = 0
Print when a NO SALE is performed? Yes = 0
No = 2
Non-add # entries are prohibited? Yes = 4
No = 0
N3
Compulsory non-add entry must match
number of digits set in the MAX DIGIT flag
below?
Yes = 1
No = 0
Print non-add on guest check? Yes = 2
No = 0
N4
Enter maximum number of digits for non-
add number entry. Zero (0) means no limit.
0-8
#/NS CASH
Repeat for another
function
N1 SUBTL 0 7 N2 N3 N4