SAM4s ER-900 Series Operator's & Programming Manual v.1.28 P-Mode Programming • 173
RECD ON ACCT 1-3 - Function Key Options
Options - Program 70 (P-Mode)
Address OPTION VALUE = SUM
N1
Key is inactive? Yes = 1
No = 0
Key is active in X control lock position
only?
Yes = 2
No = 0
Validation is compulsory? Yes = 4
No = 0
SCALE - Function Key Options
Options - Program 70 (P-Mode)
Address OPTION VALUE = SUM
N1
Key is inactive? Yes = 1
No = 0
Key is active in X control lock position
only?
Yes = 2
No = 0
Allow manual entry of weight? Yes = 4
No = 0
N2
Subtract tare weight on the scale entry? Yes = 1
No = 0
Not Used 0
Scaleable items can be open price or
scaleable entry.
Yes = 4
No = 0
N3
Weight symbol for manual entry is: Lb = 0
Kg = 1
Oz = 2
R/A CASH
Repeat for another
function
N1 SUBTL 0 7
SCALE
CASH
Repeat for another function
N1 SUBTL 0 7 N2 N3