30
-
Standard meteorological conditions (atmospheric correction value =0 ):
press: 1013hPa
temperature: 20
If the atmospheric correction is not required, please set PPM to zero.
Steps
Key
Display
1 After entering to the interface
of EDM Setting. Press [F1] (Atoms)
to enter the interface of
Atmospheric Data.
[F1]
2 Interface displays the current
settings.
3
Input the value of temperature.
example: Enter 26 and press the
key of [ENT].
The cursor moves to the setting
item of Press.
[ENT]
4 Input the value of atmospheric
pressure.
example: Enter 1020 hPa and press
the key of[ENT].Program calculates
the value of PPM and the cursor
moves to the setting item of PPM.
1
2
3
4
[ENT]