Total Station Manual
○
4 The window back to the
[Resection] window, and press
[F2] to set error limits.
○
5
Press [
◄
] \ [
►
] to turn on
the error limits status and use the
key [
▲
] \ [▼] to move the focus
down to input the every error
limit. Then press [F4] (OK) to set
and back to the [Resection]
window.
○
6
Press [F4] in [Resection]
window to start resection
measurement. It should be input
the station name and the
instrument high. Then press [F4]
(OK) go to next step.
[F4]
Input name
and IH.
+
[ENT]
[F4]
○
7
Set the first known point and
input prism high。
※
1
The title bar will display the
number of known points in the
current setting.
○
8
Turn the instrument
telescope aimed at first point and
press [F1] to finish current
measurement.
Angle measurement: press [F2]