114
68.1 ESC+BF UPC Add-on
Code(BOOKLAND)
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify UPC Add-on code (BOOKLAND)
[Format]
<BF>aabbbn~n
●Parameter
a[Narrow bar width] = Valid range : 01 to 36 dots
b[Height of barcode] = Valid range : 001 to 999 dots
n[Print data] = Numeric (0 to 9) : 2, 5 digits
[Coding Example] Narrow bar width : 03 Height of barcode : 120
<A>
<H>325<V>725<BD>H0315009827721123
<H>640<V>760<BF>0312021826
<H>655<V>730<OB>21826
<Q>1
<Z>
[Notes]
1. Barcode that other than 2-digit or 5 digit are specified will not be printed.
2. Only numeric can be specified as print data. Refer to the Bookland - Code Table.
3. There is no auto HRI specification.
4. When UPC Add-on code <BF> only is printed, it will not be readable.
It is readable only when UPC Add-on is printed with UPC code.
UPC Add-on Code(BOOKLAND)