278
DATA
12345
15.8 Intelligent Command
ESC+IZ Key Input
15.8
ESC+IZ
Hexadecimal
code
ESC
IZ
Parameter
<1B>
16
<49>
16
<5A>
16
aa,bb,cc,ddd・・・d
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The parameter preset will be invalid.
Valid range between item
The parameter preset will be invalid.
[Function]
Store the data input from the operation panel to the internal buffer.
Change the data with ↑↓ keys and move the cursor with ←→ keys.
Fix the input value with the ENTER key and store it in the internal buffer. The display transit in this state.
It is possible to store input data up to 32 digits for 16 blocks in the internal buffer (RAM).
The stored data can be recalled by the internal buffer acquisition command <IB> and use them as the print data.
[Format]
<IZ>aa,bb,cc,ddd・・d
●Parameter
a[Internal buffer number] = Valid range : 1 16
b[Input digit] = Valid range : 1 32
c[Default data] = For number of digits specified by b (Display available range: ASCII 20H-7EH)
d[Data item name] = Valid range : Only alphanumeric and symbols 16 digits
[Coding Example]
<A>
<IZ>1,5,12345,DATA
<IZ>2,4,0001,QTY
<Z>
[Notes]
1. The stored data is cleared when the printer power is off.
2. The input data is displayed up to 16 digits. When the data exceeded 16 digits, display the data with ←→ key scrolling.
3. The printer returns back to the original display after input.
4. Data input and message display is only available in the online state. Data input is not available when offline state and
error state.
5. The message is left aligned and when the message is less than the maximum display digit (16 digits), space<20>
16
is
filled.
6. The moving range by ←→ keys for input cursor depends on the input digit specification.
7. Invalid code in the displayed data will be replaced with space<20>
16
and displayed.
8. The code can be changed by ↑↓ keys is <20>
16
<7E>
16
in ASCII.
9. It is not possible to change by key input when control code (<00>
16
<1F>
16
in ASCII) is included in the default data.
Even the code has been changed by input cursor, the applicable code is discarded when storing to the internal buffer.
10. The command error occurs when input digit and the number of default data is not consistent.
11. The error will not be occurred even a printer error is detected during input waiting.
12. This command is invalid when the keys are used exclusively by <I#>1.
Key Input
QTY
0001
ENTER
ENTER
ONLINE
QTY:000000
ONLINE
QTY:000000
Internal buffer
No
Item name
Number
of digits
Data
01
DATA
5
12345
02
QTY
4
0001
03
0
04
0
05
0
06
0
07
0
08
0
09
0
10
0
11
0
12
0
13
0
14
0
15
0
16
0