172
ESC+BQ QR Code(Compatible
Manual setting abcc,(ddeeff,)g(hhhh)n
Auto setting abcc,(ddeeff,)n
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify the QR Code.
[Format]
[Manual setting] <BQ>abcc,(ddeeff)g(hhhh)n
[Auto setting] <BQ>abcc,(ddeeff) n
●Parameter
a[Error correction level(error correction)] = 1 : 7% High density Level(L)
2 : 15% Standard Level(M)
3 : 30% Ultra High Reliability Level(H)
4 : 25% High Reliability Level(Q)
b[Combine mode] = 0 : Normal mode
1 : Combine mode
c[Size of a side] = Valid range : 01~99(dots)
Example) cc=04
d[Division number of combine mode] = Valid range : 01 ~ 16
e[Sequential number of divided combine mode] = Valid range : 01 ~ 16
f[Parity data of combine mode] = Valid range : 00 ~ FF
g[Character mode] = 1 : Numeric mode
2 : Alphanumeric mode
3 : Binary mode
4 : Kanji mode
h[Number of data] = Valid range : 01~7366(dots)
n[Print data] = data
[Coding Example] Error correction level: 30%, Combine mode: Normal, Size of a side: 10
<A>
<V>100<H>200<BQ>3010,112345
<Q>2
<Z>
[Notes]
1. Specify the data that is a calculation (exclusive OR) of all divided QR code print data in HEX.
2. It is not necessary to specify the number of data parameter when the character mode is other than the binary mode.
[Important]
This command is for existing models. Using QR Code (Model 2) command <2D30> and QR Code (Model 2) command <2D31>
is recommended
QR Code
(Compatible Commands)