387
4.3 Connector Pin Assignment
The pin assignment is as follows with the Centronics standard (compatible mode).
However, the wiring diagram of the IEEE1284 standard is complied with the standard of IEEE1284 Type B connector.
4.4 Explanation of input signal
The signal lines are as follows with the Centronics standard (compatible mode).
However, the signal lines of the IEEE1284 standard are complied with the IEEE1284 standard.
A synchronized signal to read DATA 1 to DATA 8,
Low active pulse is needed.
In the data input of 8 bits parallel, DATA 1 is LSB (lease
significant bit) and DATA 8 is MSB (most significant bit).
A low active pulse signal indicating receive data intake.
A high active signal indicating the printer is impossible to
receive any data.
A high active signal indicating there is no label.
A high active signal indicating the printer is possible to receive
data.
A signal for IEEE1284 standard.
Connected to the chassis ground.
+5 V voltage at the printer.
Connected to each signal grounds.
A low active pulse signal requesting the printer initialization.
A low active pulse signal indicating an error in the printer.
A signal for IEEE1284 standard.