258
80.1 ESC+BJ,ESC+BJD Registration of
True Type Font (Compatible Commands)
<42>
16
<4A>
16
<42>
16
<4A>
16
<44>
16
(a...ab..b
c...cdddde...e
Valid range and
term of
command
When the power switch is OFF
The registered data becomes valid.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specifying the registration of True Type font.
[Format]
<BJ>(a...ab...b
<BJD>c...cdddde...e
<BJ>)
●Parameter
a[Font description] Specification of 40 bytes font
b[Date] 10 bytes date data
c[Memory offset] 5 bytes memory offset (HEX specification)
d[No. of data bytes] 0001 to 9999
e[Font data to download]
[Coding Example]
<A>
<CC>1
<BJ>(abcdefghijkabcdefghijkabcdefghijkabcdefghijk29-08-2000
<BJD>00000002203001A00490020・・・・・・・・・・0000000
<BJ>)
<Z>
[Note]
Specify slot No. registered with Card Slot for Use <CC> prior to this command by all means.
[Important]
1.Do not turn the printer power off when accessing to the memory. When the printer power is off while memory accessing,
the data in the accessed media may be corrupted.
2.This command is compatible commands for the previous model. It is recommended to register with the dedicated tool,
and print with True Type font specification <RD> (or Call and Print of Font & Logo <RF>).
Registration of True Type Font
(Compatible Commands)