197
ESC+BV MAXI Code (Compatible
a,b,c,ddddddddd,eee,fff,n~n
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify the MaxiCode.
[Format]
<BV>a,b,c,ddddddddd,eee,fff,n~n
●Parameter
a[Symbol number] = Range : 1~8
b[Symbol digit] = Range : 1~8
c[Mode] = 2 : For carrier
3 : For carrier
4 : Standard code
6 : For reading device
d [Postal code] = Valid range : 0~999999999 (mode 2)
000000~999999(mode 3)
* Maximum 9 digits for mode 2(only numeric)
Fixed to 6 digits for mode 3 (upper case only for alphabet)
.
e[Country code] = Valid range : 001~999
f [Service class] = Valid range : 001~999
n[Low priority message] = Alphanumeric, symbols
[Coding Example]
<A>
<V>100<H>200<BV>1,1,2,123456789,001,002,SAHTHA
<Q>2
<Z>
[Notes]
1. The size of the MaxiCode does not vary depending on the number of print data.
2. The code will not be printed when a parameter other than above is specified or number of print data does not match.
3. Specify more than 12 for the print data when mode 4 or 6 is specified. The MaxiCode that print data are equal or less than 11
cannot be read by scanners.
[Important]
This command is for existing models. Using Maxi Code command <2D20> is recommended
The maximum number of print
data
Fixed to 3 digits
(Numeric only)
Fixed to 3 digits
(Numeric only)
Fixed to 6 digits
(alphanumeric)
Maxi Code
(Compatible Commands)