241
13.6 Memory Card
ESC+YR Format Call
13.6
ESC+YR
Hexadecimal
code
ESC
YR
Parameter
<1B>
16
<59>
16
<52>
16
,aaaaa
Initial value
Nil
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The set parameter is in effect until a new specification is made.
Valid range between item
The set parameter is in effect until a new specification is made.
[Function]
Invoking and printing out the format registered with Registration of Format <YS>.
[Format]
<YR>,aaaaa
●Parameter
aaaaa[Format registration No.] = Valid range : 00001 to 99999
[Coding Example]
<A>
<CC>1
<YR>,1
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
[Notes]
1. This command cannot invoke multiple formats between Start of Data Transmission <A> and End of Data Transmission
<Z>.
2. Use this command and Print of Field </D> as a set.
3. The error occurs when unused or the slot which the printer is allocated is specified (Refer to Card Slot for Use <CC>).
[Important]
Do not turn the printer power off when accessing to the memory. When the printer power is off while memory accessing, the
data in the accessed media may be corrupted.