EasyManua.ls Logo

SATO s84ex - ESC+ID Job ID Number

SATO s84ex
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
4.1 Control
4.1 ESC+ID Job ID Number
ESC+ID
Hexadecimal
code
ESC
ID
Parameter
<1B>
16
<49>
16
<44>
16
aa
Initial value
a=<20>
16
Valid range and
term of
command
When the power switch is OFF
The set parameter is not maintained.
Valid range within item
The set parameter is in effect until a new specification is made.
Valid range between item
The parameter preset will be invalid.
[Function]
Specifying job ID number for status return.
[Format]
<ID>aa
●Parameter
a[Job ID number] = Valid range: 00 to 99
[Coding Example] Job ID number: 01
<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Notes]
1. When a status return is used for communication protocol, the specified job ID No. can be set to the telegraphic status.
2. Status can be confirmed sending status request (ENQ).
3. Include this command within an item and use when printing by Start of Data Transmission <A> ~ End of Data Transmission
<Z>.
4. The valid range of the job ID is "0000 - 9999" and "*****" when using Status 5. When "*****" is specified, the item is not
controlled by the job ID number.
[Remarks]
1. In status return communication protocol, this command becomes valid when a status request (ENQ) is received while printing
(Including when QTY≠0, Offline and Error).
2. In status return communication protocol, if status request (ENQ) is received when printing is not in progress (QTY=0, No
received data when power is ON), space (20H) will be set to status and returned.
3. When Job ID Number <ID> is used more than twice within the items of <A> and <Z>, the last specified value becomes valid.
4. For more information, refer to the “Interface Specifications
Job ID Number

Table of Contents

Other manuals for SATO s84ex

Related product manuals