10
Control Command 5
1.1 ESC+A Start of Data Transmission
Valid range and
term of
command
When the power switch is OFF
The set command is not maintained.
The set command becomes invalid.
Valid range between items
The set command becomes invalid.
[Function]
Specifying the start of data transmission.
[Format]
<A>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Notes]
1. Indicates the start of the item and to be placed at the head of the item.
2. Use <A> and End of Data Transmission <Z> as a set of commands.
[Remarks]
1. Setting value of all commands excluding a part of system commands will be set to default.
2. If not specified this command, printing will not be performed.
Start of Data Transmission