169
Valid range and
term of
command
When the power switch is OFF
The set parameter is maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
[Function]
Specify GS1 DataMatrix.
[Format](setting part)
<2D51>,aa,bb,ccc,ddd
●Parameter
a[Horizontal cell size] = Valid range : 01 ~ 99(dots)
b[Vertical cell size] = Valid range : 01 ~ 99(dots)
c[Number of cells per line] = Valid range : 010~144
000 : Auto setting
d[Number of cell l lines] = Valid range : 008~144
000 : Auto setting
[Format](data part)
<DN>mmmm,n~n
●Parameter
m [Number of data] = Valid range : 1~3116
n [Print data] = data
* Specify [7EH, 7EH] when printing 7EH.
* Specify [1BH, 1BH] when printing 1BH.
* Specify [1BH, 31H] when printing FNC1.
* The contents of the code will not be guaranteed when parameter other than above is specified or number of print data does
not match.
[Coding Example] Horizontal cell size: 3dots, Vertical cell size: 3dots
<A>
<V>100<H>200<2D51>,03,03,000,000
<DN>0014,<1B>161100123456789
<Z>
* <1B>
16
is referring to 1BH in the character code.
[Notes]
1. The code will not be printed when a parameter other than above is specified or number of digits in the number of data and
print data
do not match.
2. Specify more than 2mm blank space around the DataMatrix code as a margin for scanner readability when specifying the
print format.
3. Specify [7EH, 7EH] when printing 7EH. The number of data is [0002].
4. When [7EH] is specified solely, the command error occurs and the code will not be printed.
5. Specify [1BH, 1BH] when printing 1BH. The number of data is [0002].
6. Specify [1BH, 31H] when printing FNC1. The number of data is [0002].
7. When [1BH] is specified solely, the printing and the contents are not guaranteed.
8. When auto setting (000) is specified in the "number of cells per 1 line" and "number of cell lines", square DataMatrix is printed.
9. When the same value other than 000 is specified (manual setting) in the "number of cells per 1 line" and "number of cell lines",
square DataMatrix is printed.
10. When different value other than 000 is specified (manual setting) in the "number of cells per 1 line" and "number of cell lines",
rectangle DataMatrix is printed.
11. The number of data can be specified in the data part depends on the data format. Available number of data is as follows.
(Number of cells is auto setting or the maximum cell number is specified):
GS1 DataMatirx