311
16.8 RFID Command
ESC+RA RFID mode setting
16.4
ESC+RA
Hexadecimal
code
ESC
RA
Parameter
<1B>16
<52>16<41>16
a(,Ec:b)(,Ce:c)(,To:ddd)(,Pw:eee)(,Pr:fff)(,Mr:g)(,Ed:h)(,Es:i)(,Eo:j)
(,Pl:k)(,Pm:l)(,Iv:m)(,It:n)(,Rc:o)(,Rs:p)(,Ma:q)(,Mb:r)(,Mc:s)(,Me:t)
(,Mf:u)(,Mg:v)(,La:w)(,Lb:x)
Initial value
Refer to the table below.
Valid range and
term of
command
When the power switch is OFF
The set parameter is maintained.
Valid range within item
The parameter preset will be invalid. (Valid when Rs: 0 is
specified)
Valid range between item
The parameter preset will be invalid. (Valid when Rs: 0 is
specified)
[Function]
Switch between Normal mode and RFID enabled mode, and change RFID settings.
[Format]
<RA>a (,Ec:b)(,Ce:c)(,To:ddd)(,Pw:eee)(,Pr:fff) (,Mr:g)(,Ed:h)(,Es:i)(,Eo:j)(,Pl:k)(,Pm:l)(,Iv:m)(,It:n)(,Rc:o)
(,Rs:p)(,Ma:q)(,Mb:r)(,Mc:s)(,Me:t)(,Mf:u)(,Mg:v)(,La:w)(,Lb:x)
●Parameter (All parameters should be ASCII format)
a = [Operation mode] : Valid range "0,2"
0: RFID disabled mode
2: RFID enabled mode
When the operation mode setting is 2: RFID enabled mode, you can specify the extended parameters to set each of detailed
setting of RFID. Specify the setting category by identifier, and set the value after the identifier to the designated category.
(Rebooting is necessary after setting change)
Extended parameter
Item
Identifier
Category/Description
Valid range
b
”Ec:”
Number of retries
Specify the upper limit of number of retry in the range from 0 to 9 when tag error is
occurred with EPC code write command <IP0>. (Default Value: 1)
"0" to "9"
1 digit
c
”Ce:”
Print restraint function at the time of command error
When the error occurs in the command contained in the RFID print item, set
whether or not to print.
0(30H) Don't print (Default)
1(30H) Print
When "Don’t print" is set, and a command error and a parameter error occur in the
item including the RFID print -related command, the printer discards the item in
error, ring the buzzer, stops printing and goes to OFFLINE.
(0,1)
1 digit
ddd
”To:”
Tag offset
Change the tag offset. Unit is in mm. From 0 to 240 can be specified. (Default
Value: 0)
Specify the value that does not exceeds the label size and the size specified with
<A1> command.
Note that a white streak may appears at the pause position. You need to
consider it to avoid as it affects the print layout.
"0" to "240"
Maximum 3
digits
eee
”Pw:”
Radio output power setting (at writing)
Specify the value of radio output power setting of RFID module. The value is dBm x
10.
Example: 17.0 dBm is 170
The value is sent to RFID module after rebooting, and the specified radio output
power becomes valid. (Default Value: 100)
Use "Antenna Output ESC+IP5" when the specified radio output power needs to be
valid immediately.
"0" to "240"
Maximum 3
digits
(Necessary
to reboot
after
changing)
fff
”Pr:”
Radio output power setting (at reading)
Specify the value of radio output power setting of RFID module. The value is dBm x
10.
Example: 17.0 dBm is 170
The value is sent to RFID module after rebooting, and the specified radio output
power becomes valid. (Default Value: 100)
Use "Antenna Output ESC+IP5" when the specified radio output power needs to be
valid immediately.
"0" to "240"
Maximum 3
digits
(Necessary
to reboot
after
changing)
RFID mode setting